Valve Fire Test (API 607, API 6FA)

Valve Fire Test (API 607, API 6FA)

Valve fire test / fire-safe test

Verifies packing sealing fire resistance under high-temperature burning

Samples required

Product Details

Valve fire test, also called fire safe test, verifies that a valve can maintain the required packing and body sealing performance after being exposed to a defined high-temperature flame for a specified period. It is a mandatory safety verification for valves used in flammable service in oil, gas, petrochemical, refining and offshore applications, and it is the basis of the valve fire test certificate.

Applicable Standards

  • API 607 (2022 edition) - fire test for quarter-turn valves (ball, butterfly, plug) and valves with non-metallic seats
  • API 6FA (2026 edition) - fire test for pipeline valves (gate, globe, check) and wellhead equipment
  • ISO 10497 - general requirements and qualification method for valve fire testing
  • API Spec 6A - fire requirements for wellhead and christmas tree equipment

Valve Fire Test Procedure

  1. Submit the sample and technical data (size, pressure class, materials, applicable standard)
  2. Define the test parameters: burn temperature curve, burn duration, cooling method, operational test requirements
  3. Ambient baseline seat test, then burn (approx. 30 minutes), operational test during burn, then post-cooling low and high pressure seat tests
  4. Issue the third-party valve fire test report and fire test certificate

Valve Fire Test Cost

The fire test cost is mainly determined by valve size and pressure class, the number of applicable standards (API 607, API 6FA and ISO 10497 can be assessed separately or combined), the number of samples, whether on-site witnessing is required, and whether expedited service is needed. Burn duration and assessment items differ between standards, so the cost varies accordingly. Send us your sample and applicable standard and we will provide a detailed test plan and quotation within 1 working day.

Sample Submission

The fire test requires a complete valve sample to be shipped to our laboratory. Product drawings, material certificates and nameplate photos are recommended so that the test parameters can be confirmed. Contact: +86-18731031297 (WeChat available).

Valve Fire Test FAQ

What is the difference between API 607 and API 6FA?

API 607 applies to quarter-turn valves (ball, butterfly, plug valves) while API 6FA applies to pipeline valves (gate, globe, check valves) and wellhead equipment. The burn curve, burn duration and assessment items differ, so the applicable standard depends on the valve type and the purchaser's specified requirement.

How long does a valve fire test take?

The standard lead time for a single sample is 1 to 2 weeks, covering test execution and report preparation. It depends on the number of applicable standards and sample readiness; expedited service is available on request.

How much does a valve fire test cost?

Fire test cost is calculated from valve size, pressure class, number of standards and number of samples, and is quoted after sample evaluation. Send us the product specification and applicable standard and we will provide a test plan and quotation within 1 working day.

How long is a valve fire test certificate valid?

A third-party fire test report and certificate are normally tied to the design status of that valve model. If the design, materials or manufacturing process change, the fire qualification needs to be re-assessed.